Timing Messages

Report Title Gowin Timing Analysis Report
Design File C:\Gowin\Workspace\simple_io8\impl\gwsynthesis\simple_io8.vg
Physical Constraints File C:\Gowin\Workspace\simple_io8\src\simple_io8.cst
Timing Constraint File ---
GOWIN version V1.9.7.06Beta
Part Number GW1N-UV4LQ144C6/I5
Device GW1N-4B
Created Time Sat Jun 05 11:00:53 2021
Legal Announcement Copyright (C)2014-2021 Gowin Semiconductor Corporation. All rights reserved.

Timing Summaries

STA Tool Run Summary:

Setup Delay Model Slow 2.375V 85C
Hold Delay Model Fast 2.625V 0C
Numbers of Paths Analyzed 8
Numbers of Endpoints Analyzed 8
Numbers of Falling Endpoints 0
Numbers of Setup Violated Endpoints 0
Numbers of Hold Violated Endpoints 0

Clock Summary:

Clock Name Type Period Frequency(MHz) Rise Fall Source Master Objects

Max Frequency Summary:

NO. Clock Name Constraint Actual Fmax Logic Level Entity

Total Negative Slack Summary:

Clock Name Analysis Type Endpoints TNS Number of Endpoints

Timing Details

Path Slacks Table:

Setup Paths Table

Report Command:report_timing -setup -max_paths 25 -max_common_paths 1

Nothing to report!

Hold Paths Table

Report Command:report_timing -hold -max_paths 25 -max_common_paths 1

Nothing to report!

Recovery Paths Table

Report Command:report_timing -recovery -max_paths 25 -max_common_paths 1

Nothing to report!

Removal Paths Table

Report Command:report_timing -removal -max_paths 25 -max_common_paths 1

Nothing to report!

Minimum Pulse Width Table:

Report Command:report_min_pulse_width -nworst 10 -detail

Nothing to report!

Number Slack Actual Width Required Width Type Clock Objects

Timing Report By Analysis Type:

Setup Analysis Report

Report Command:report_timing -setup -max_paths 25 -max_common_paths 1

No setup paths to report!

Hold Analysis Report

Report Command:report_timing -hold -max_paths 25 -max_common_paths 1

No hold paths to report!

Recovery Analysis Report

Report Command:report_timing -recovery -max_paths 25 -max_common_paths 1

No recovery paths to report!

Removal Analysis Report

Report Command:report_timing -removal -max_paths 25 -max_common_paths 1

No removal paths to report!

Minimum Pulse Width Report:

Report Command:report_min_pulse_width -nworst 10 -detail

Nothing to report!

High Fanout Nets Report:

Report Command:report_high_fanout_nets -max_nets 10

FANOUT NET NAME WORST SLACK MAX DELAY

Route Congestions Report:

Report Command:report_route_congestion -max_grids 10

GRID LOC ROUTE CONGESTIONS
R12C1 2.78%
R12C9 2.78%
R12C17 2.78%
R12C25 2.78%
R20C36 2.78%
R15C38 2.78%
R17C38 2.78%
R20C25 2.78%
R15C22 1.39%
R15C5 1.39%

Timing Exceptions Report:

Setup Analysis Report

Report Command:report_exceptions -setup -max_paths 5 -max_common_paths 1

No timing exceptions to report!

Hold Analysis Report

Report Command:report_exceptions -hold -max_paths 5 -max_common_paths 1

No timing exceptions to report!

Recovery Analysis Report

Report Command:report_exceptions -recovery -max_paths 5 -max_common_paths 1

No timing exceptions to report!

Removal Analysis Report

Report Command:report_exceptions -removal -max_paths 5 -max_common_paths 1

No timing exceptions to report!

Timing Constraints Report:

SDC Command Type State Detail Command